페이지 선택

G238-G398 Mycoplasma PCR Detection Kit & Elimination Combo Kit

Cat. No.
G238-G398
Unit
1 Combo Kit
Cat. No. G238-G398
Name Mycoplasma PCR Detection Kit & Elimination Combo Kit
Unit
1 Combo Kit
Category PCR, qPCR, and RT
Description Enjoy superior performance at lower costs!

abm's Mycoplasma PCR Detection Kit & Elimination Combo Kit combines the power of our bestselling kit Mycoplasma PCR Detection Kit (Cat. No. G238) and MycoAway™ Mycoplasma Elimination Cocktail (1000X) (Cat. No. G398).

The Mycoplasma PCR Detection Kit offers highly specific and sensitive detection of 200+ strains of Mycoplasmas in less than 2 hours. This bestselling kit is designed to minimize false positives, ensuring quick and reliable routine screening of cell cultures. A recent official publication by a national public health agency found that our kit out-performs Sigma and Lonza's kits while being 6X less expensive than ATCC's kit (Russell et al., 2020)Furthermore, the MycoAway™ Mycoplasma Elimination Cocktail (1000X) is a specially formulated agent to effectively clear cells from Mycoplasma contamination in both adherent and suspension cells. Our potent formulation is non-toxic and eliminates 70+ species of Mycoplasma in as little as 2-3 weeks (4-6 cell passages)! The combination of these two kits ensures complete protection of your cell lines!

 

Unit 100 rxn
Storage Condition Store at -20°C. This product is stable for 2 years from the date of shipping if stored and handled properly.

For a T75 flask, we recommend using 5ml - 7ml of our Applied Cell Extracellular Matrix (G422).

In rare cases, there may be a weak non-specific binding to a region of human gDNA due to the degenerate nature of the primers that can amplify a weak 250bp band in human cell samples. Your sample can be considered as negative for mycoplasma, as mycoplasma amplicons will be 370-550bp in size. You can try to increase the annealing temperature of the PCR program to 60°C to reduce this non-specific amplification.

This could occur in cases where the PCR machine does not ramp temperature fast enough. We suggest trying touchdown PCR in these situations.

Typically centrifugation is not required, however if your sample looks particularly cloudy, you can centrifuge it before use.

For best results, PCR components should be aliquoted if you are frequently testing small quantites of samples. E.g. If you are only testing 1-5 samples each time, aliquoting is recommended to reduce the number of freeze/thaw cycles.

Serum will not have any inhibitory effects on PCR. However, if your media contains >20% serum and if it is too viscous, you can dilute with either basal media or Nuclease-free water by tenfold prior to mycoplasma detection.

There are no references for this product yet!

This product has no review yet.

Controls and Related Product:

SafeView™ Classic


Cat. No.
G108
Unit 1.0 ml

Safe-Green™


Cat. No.
G108-G
Unit 1.0 ml

Safe-Red™ Gel


Cat. No.
G680
Unit 1.0 ml

T4 DNA Ligase


Cat. No.
G467
Unit 200 U (200 μl)

Safe-Red™


Cat. No.
G108-R
Unit 1.0 ml

DNA Purification Magnetic Beads (5 ml)


Cat. No.
G950
Unit 4 x 1.25 ml

Column-Pure Gel and PCR Clean-Up Kit


Cat. No.
D516
Unit 100

Pro Ligation-Free Cloning Kit (20 reactions)


Cat. No.
E086
Unit 20 Reactions