Thistle Scientific product

EV2xxx Series Maxi Power Supply

Thistle Scientific supplies electrophoresis systems, gel documentation, PCR thermal cyclers, centrifuges and laboratory equipment.

EV2xxx Series Maxi Power Supply
1 / 2

EV2xxx Series Maxi Power Supply

At a Glance

  • Various running modes
  • On screen help in 4 languages
  • Password protection
  • Data-logging
  • Safety features
CAT.NO: EV2310Request a Quote
Overview

The front panel and graphical display are designed for ease of use. The display provides all useful information during runs and will show an on screen help to guide the user in setting up the power supply.

In Simple Mode you just have to set your power supply tothe desired parameters and press run. EV2000 series has a firmware upgrade capability so future improvements and features will always be available.

Moreover EV2000 series has continuous logging combined with a real time clock so it’s possible to get an overview of previous runs, including possible down-times in case of mains power failures.

The complete EV series can keep it’s voltage constant at low currents without problem and will keep on functioning at low and high temperatures.

Features include:

On screen help in 4 languages to assist setting up the power supply parameters and solve errors.

Firmware updates allows for upgrades to the latest version via the USB interface. Feature requests can also be implemented via the firmware system.

Real Time Clock date and time are kept in a battery backup system and is used logging an electrophoresis run.

Various running modes:

Simple Mode: just set voltage, current, power and time for a routine electrophoresis run.

9x9 Method Programming Mode: Up to 9 different programs, each with 9 steps, can be stored in the non-volatile memory. Each step is able to recall a next one, providing a flexible multiple step function for special techniques. Parameters of the running step can be changed temporarily without interrupting the run.

Voltage Ramp Mode: a linear voltage gradient for any step provided the limiting current or power is not attained.

Timer Mode: Timer or volt-hour controlled operation will automatically stop the run and sound an alarm.

Automatic cross-over - Each model has constant voltage, constant current, constant power capabilities with automatic cross-over and shows which parameter is kept constant.

Automatic recovery after power failure

Password protection

Specifications
SKUEV2230EV2230$EV2310EV2310$EV2320EV2320$EV2650EV2650$
Unit Dimensions (cm)24 x 20 x 13 cm24 x 20 x 13 cm24 x 20 x 13 cm24 x 20 x 13 cm24 x 20 x 13 cm24 x 20 x 13 cm24 x 20 x 13 cm24 x 20 x 13 cm
Weight (Kg)66666666
Timer0...99:59 h0...99:59 h0...99:59 h0...99:59 h0...99:59 h0...99:59 h0...99:59 h0...99:59 h
Resolution1 V, 1 mA, 1 W1 V, 1 mA, 1 W1 V, 1 mA, 1 W1 V, 1 mA, 1 W1 V, 1 mA, 1 W1 V, 1 mA, 1 W1 V, 1 mA, 1 W1 V, 1 mA, 1 W
Password ProtectionYesYesYesYesYesYesYesYes
Control InterfaceUSBUSBUSBUSBUSBUSBUSBUSB
Input Voltage230110230110230110230110
Operating Temperature0...40°C0...40°C0...40°C0...40°C0...40°C0...40°C0...40°C0...40°C
Operating environment0...95%, non condensing0...95%, non condensing0...95%, non condensing0...95%, non condensing0...95%, non condensing0...95%, non condensing0...95%, non condensing0...95%, non condensing
Displaygraphicalgraphicalgraphicalgraphicalgraphicalgraphicalgraphicalgraphical
Compliance MarksCECECECECECECECE
Maximum Voltage (V)15001500300300030003000600600
Maximum Current (mA)30030010001000150150500500
Maximum Power (W)150150150150150150150150
Number of Output Pairs44444444
Operating ModesConstant Parameter, Programmable 9 Step ProgrammeConstant Parameter, Programmable 9 Step ProgrammeConstant Parameter, Programmable 9 Step ProgrammeConstant Parameter, Programmable 9 Step ProgrammeConstant Parameter, Programmable 9 Step ProgrammeConstant Parameter, Programmable 9 Step ProgrammeConstant Parameter, Programmable 9 Step ProgrammeConstant Parameter, Programmable 9 Step Programme
Output Diameter (mm)44444444
Minimum Load Resistance300 Ω300 Ω10 Ω10 Ω600 Ω600 Ω30 Ω30 Ω
No Load Detectiontruetruetruetruetruetruetruetrue
Overload Detectiontruetruetruetruetruetruetruetrue
Ground Leakage Detectiontruetruetruetruetruetruetruetrue
Documents
All Variations
Need assistance?
Contact our experts for support and fast quotations.
(주)이츠바이오
07532 서울특별시 강서구 양천로 551-17 한화비즈메트로 1차 812호
T : 02-3462-8658  F : 02-3462-8659
E-mail : info@itsbio.co.kr
ITSBio, Inc.
812, Hanwha Bizmetro A-dong, 551-17 YangcheonRo, Gangseo-Gu, Seoul, 07532, Korea, Republic of
T : +82-2-3462-8658  F : +82-2-3462-8659
E-mail : info@itsbio.co.kr
Privacy Policy|Terms|© 2026 ITS BIO. All rights reserved.
Online Message
Send to info@itsbio.co.kr