Cleaver Scientific product
EV2xxx Series Maxi Power Supply
Electrophoresis systems, gel documentation, power supplies and laboratory equipment from Cleaver Scientific.


1 / 2
EV2xxx Series Maxi Power Supply
At a Glance
- Various running modes
- On screen help in 4 languages
- Password protection
- Data-logging
- Safety features
CAT.NO: EV2310Request a Quote
Overview
Specifications
| SKU | EV2230 | EV2230$ | EV2310 | EV2310$ | EV2320 | EV2320$ | EV2650 | EV2650$ |
|---|---|---|---|---|---|---|---|---|
| Unit Dimensions (cm) | 24 x 20 x 13 cm | 24 x 20 x 13 cm | 24 x 20 x 13 cm | 24 x 20 x 13 cm | 24 x 20 x 13 cm | 24 x 20 x 13 cm | 24 x 20 x 13 cm | 24 x 20 x 13 cm |
| Weight (Kg) | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 |
| Timer | 0...99:59 h | 0...99:59 h | 0...99:59 h | 0...99:59 h | 0...99:59 h | 0...99:59 h | 0...99:59 h | 0...99:59 h |
| Resolution | 1 V, 1 mA, 1 W | 1 V, 1 mA, 1 W | 1 V, 1 mA, 1 W | 1 V, 1 mA, 1 W | 1 V, 1 mA, 1 W | 1 V, 1 mA, 1 W | 1 V, 1 mA, 1 W | 1 V, 1 mA, 1 W |
| Password Protection | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Control Interface | USB | USB | USB | USB | USB | USB | USB | USB |
| Input Voltage | 230 | 110 | 230 | 110 | 230 | 110 | 230 | 110 |
| Operating Temperature | 0...40°C | 0...40°C | 0...40°C | 0...40°C | 0...40°C | 0...40°C | 0...40°C | 0...40°C |
| Operating environment | 0...95%, non condensing | 0...95%, non condensing | 0...95%, non condensing | 0...95%, non condensing | 0...95%, non condensing | 0...95%, non condensing | 0...95%, non condensing | 0...95%, non condensing |
| Display | graphical | graphical | graphical | graphical | graphical | graphical | graphical | graphical |
| Compliance Marks | CE | CE | CE | CE | CE | CE | CE | CE |
| Maximum Voltage (V) | 1500 | 1500 | 300 | 3000 | 3000 | 3000 | 600 | 600 |
| Maximum Current (mA) | 300 | 300 | 1000 | 1000 | 150 | 150 | 500 | 500 |
| Maximum Power (W) | 150 | 150 | 150 | 150 | 150 | 150 | 150 | 150 |
| Number of Output Pairs | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 |
| Operating Modes | Constant Parameter, Programmable 9 Step Programme | Constant Parameter, Programmable 9 Step Programme | Constant Parameter, Programmable 9 Step Programme | Constant Parameter, Programmable 9 Step Programme | Constant Parameter, Programmable 9 Step Programme | Constant Parameter, Programmable 9 Step Programme | Constant Parameter, Programmable 9 Step Programme | Constant Parameter, Programmable 9 Step Programme |
| Output Diameter (mm) | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 |
| Minimum Load Resistance | 300 Ω | 300 Ω | 10 Ω | 10 Ω | 600 Ω | 600 Ω | 30 Ω | 30 Ω |
| No Load Detection | true | true | true | true | true | true | true | true |
| Overload Detection | true | true | true | true | true | true | true | true |
| Ground Leakage Detection | true | true | true | true | true | true | true | true |