ITS BIO

PLAS-LABS

Controlled-environment glove boxes, laboratory enclosures, and animal care equipment.

Poultry Isolators · 1 / 2

Poultry Isolators image 1

Animal Care & Research

Poultry Isolators

Designed to protect both your fowl, and your personnel.

The Plas-Labs’ goal pertaining to H.E.P.A. filtration of its chambers is to ensure absolute filtration, yet make filter change-over simple and quick. Both the H.E.P.A. filter and blue pre-filters can be changed in seconds.
Request a Quote

These poultry isolation units are designed to protect both your fowl and personnel from cross contamination. They are ideal for either acute or chronic studies. The isolation cubicles are match die-molded of “hi-tech” thermoplastic allowing for autoclaving or steam sterilization. The problem of hypothermia is eliminated. Individual cubicles can be removed for cleaning, but it is not normally necessary. The polycarbonate doors are mounted using stainless steel “slip-a-part” hinges for easier cleaning.

Shown with optional escape shield (part number: 800-PIU/ES)

Standard Features of the Poultry Isolators:

  • Match die-molded animal housings. With autoclavable or steam cleaning capabilities.
  • Stainless steel support frame (trolley) with casters, brakes and locks.
  • Removable polycarbonate front door with slip-a-part stainless steel hinges.
  • High temperature gasket material.
  • Electrical control panel can be removed during cleaning.
  • Digital temperature controller and thermocouple.
  • Red heat lamp with adjustable intensity.
  • Gravity fed stainless steel feeder chute and adjustable feed box with sight gauge.  Capacity: 6 to 12 pounds. (Depends on size of cubicle)
  • Gravity fed adjustable watering “T” with two or three water cups. All stainless steel.
  • Fast acting “squeeze” adjuster for the watering “T”.
  • Stainless steel floor grid.
  • Formed white waste pan with rounded corners.
  • Lower “trap” door for removing the waste pan. No disruption of the birds.
  • Cylindrical H.E.P.A. filters for air make up and exhaust. Allowing for easy and quick filter changing.
  • Reusable (hand washable) polyester pre-filters rated MERV 4.
  • Squirrel cage blower for air make up or exhaust. Negative pressure standard, but positive pressure is available upon request. Includes an orifice for testing the H.E.P.A. efficiency. “DOP/PAO” testing capable.
  • Electrical set-up for either 115-120 or 220-240 volts.
  • Standard Plas-Labs’ 12 month warranty against defective materials and workmanship. (Not the gloves or the filters).
Poultry Isolators

Specifications

Vertical Configurations.                               PIU_36_2main.jpg

Catalog Number

Cubicle Size

Number of cubicles

FIC-30-1/PIU

30" x 30" x 30"

One (1)

FIC-30-2/PIU

Each cubicle:  30 x 30 x 30"

Two (2)


Horizontal Configurations.                    PIU_Horizontal.jpg

FIC-36-1/PIU

36" x 36" x 36"

One (1)

FIC-36-2/PIU

Each cubicle:  36 x 36 x 36"

Two (2)

Electrical requirements

North America
Poultry Isolators
Electrical Requirements:  115-120 Volts, 60 Hz. 12 Amps
Export
Poultry Isolators
Electrical Requirements:  220-240 Volts, 50 Hz. 5 Amps

Housing Feeder & Watering Details

Poultry Isolators

Feeder box in lower position. Seated in lower bracket for younger chicks.

Revised glove port plug, prevents birds from getting into glove port and suffocating.

Poultry Isolators

Stainless steel feeder chute.

Stainless steel feed box with sight gauge. (Elevated position).

Removable stainless steel grid floor.

Poultry Isolators

New “Coiled” flexible water hose can easily be attached to your house water supply.

New “Squeeze” adjustment for raising and lowering the water “T” system.

Stainless steel watering cups and “T” bar.

Poultry Isolators
Stainless steel feeder
chute and removable
chute plug.

Optional Accessories for the Poultry Isolation Units:

  • Ambidextrous white Hypalon gloves. Glove port plugs are included. Plugs prevent birds from entering ports and suffocating. (Catalog: 800-PIU/PORTS)
  • Access port for removing sick, injured, or dead birds.    (Catalog: 800-PIU/ACCESS/P)
  • Interior “anti-escape” shield (polycarbonate).  Catalog: 800-PIU/ES

REMOVABLE WASTE PAN AND LOWER TRAP DOOR (Included)

  •  Each housing cubicle includes a formed white plastic waste pan that is removable without disturbing your birds.
  •  The lower trap door is standard, but can be eliminated if the customer prefers.
  •  New “Sealed” living hinge for lower trap clean-out door.
PIU_top.jpg

800-PIU/PORTS White hypalon ambidextrous gloves and ports.
800-PIU/ACCESS/P, Access port with inner and outer doors.

AccessDoor.png

800-PIU/ACCESS/D. Flat access door only.

EscapeSheild.png

800-PIU/ES, Escape Shield

FIC_30_2open.png

Removable cubicle divider

HEPA Filter & Exhaust Blower Housing Details

  • Choose negative or positive pressure set-up. Pressure direction is determined by end-user’s requirements.
  • Filter housings have stainless steel “slip-a-part” hinges and clamps for easy removal when cleaning.
  •  Cylindrical H.E.P.A. filters are 8” (203 mm) in diameter. 99.99% @ .3μm .
  • The blower housing also has the same “slip-a-part” hinge and clamping system.
  •  Pre-filters are hand washable, three (.5μ) micron spun polyester.
Poultry Isolators
The thermocouple wire is
inserted between the HEPA
filter and inner cage wall.
Poultry Isolators
Open clear plastic housing to
install the replacement HEPA
filter.
Poultry Isolators
The blue “pre-filter” is placed in
front of the exhaust HEPA filter.
Place pre-filter on the outside of
the air make up filter.

Removable Electric Control Panel

All electrical controls are mounted on a stainless steel panel that can be removed in seconds for cleaning the isolation unit. Using our unique “Key Way” technique, no tools are required.

  • Two (2) upper “Key Way” slots for mounting or removing control panel.
  • New digital heat control module, #DBS 1000 for upper housing thermocouple. Just push a button and scroll to your desired temperature.
  • Temperature thermocouple. The tip is placed inside the exhaust H.E.P.A. filter housing. Same on the bottom H.E.P.A.
  •  Electrical sockets for both the upper heat lamp and blower.
  •  Variable speed controls for fans, (blowers).
  • 20 Amp Ground Fault Interrupter (G.F.C.I.). Safety socket. Reset button.
  •  Electrical sockets for both the lower heat lamp and the blower.
  • New digital heat control module, #DBS 1000 for lower housing with thermocouple. Just push a button and scroll to your desired temperature.
Poultry Isolators
Need assistance?
Contact our experts for support and fast quotations.
(주)이츠바이오
07532 서울특별시 강서구 양천로 551-17 한화비즈메트로 1차 812호
T : 02-3462-8658  F : 02-3462-8659
E-mail : info@itsbio.co.kr
ITSBio, Inc.
812, Hanwha Bizmetro A-dong, 551-17 YangcheonRo, Gangseo-Gu, Seoul, 07532, Korea, Republic of
T : +82-2-3462-8658  F : +82-2-3462-8659
E-mail : info@itsbio.co.kr
Privacy Policy|Terms|© 2026 ITS BIO. All rights reserved.
Online Message
Send to info@itsbio.co.kr