EU 0.1 ml Thin-wall tube, B77201

0.1/0.2 ml PCR Tubes

EU 0.1 ml Thin-wall tube

LP,LF,Optical Indented wide area Cap (0.1 ml)

Cat.No B77201

Natural, Bag of 1000 tubes

Request a Quote

Overview

Fits almost all PCR and qPCR (fast) cycler models which accept low profile products. See compatibility list at www.bioplastics.com . Designed for PCR and qPCR applications. For qPCR with optical reading trough the cap frosted tubes are recommended.

Specifications

Colour
Natural
Quantity
bag of 1000
Low Profile
Height: 15.6 - 16.6 mm, 0.61 - 0.65 inch. 0.1 ml. Used in most fast cyclers, and has improved evaporation characteristics
Frosted (light)
This product has a frosted outer texture and has a moderate signal to noise ratio in qPCR
Thin Wall
This product has a thin wall.
O-Type Material
This product is made of a different blend of PP, designed for PCR and qPCR applications.
Evaporation Grade 1
Loss of PCR volume is less than 3%. It’s possible to PCR in as less as 5 µl.
Extra Low Adhesion
This product is specially treated to reduce the binding of protein.
Optical
This product has the following optical clear area of ... mm² (5.9, 6.6, 7.0, 7.1, 12.6 mm²)
DNA, DNase, RNA, RNase & Pyrogen Free
This product is free of DNa(se), RNa(se), Pyrogens & metals.
Autoclavable
This product is autoclavable.
qPCR Grade 1
This product has enhanced signal-to-noise ratio if frosted.

Other ordering options

  • B77202Red, Bag of 1000 tubes
  • B77203Blue, Bag of 1000 tubes
  • B77204Green, Bag of 1000 tubes
  • B77205Yellow, Bag of 1000 tubes
  • B77206Orange, Bag of 1000 tubes
  • B77207Violet, Bag of 1000 tubes

Instrument compatibility

This product fits 293 (q)PCR instruments

Read each fit indication together with the grid or tear-off conditions in the same row. Grid descriptions identify the required shape.

ManufacturerInstrumentBlockSupport
AcuGen SystemsAG-9600 thermal station96 x 0.2mlFits in whole or in part
Analytik-JenaAlpha SC48 x 0.2mlFits in whole or in part
Analytik-JenaAlpha SC48-96 48 x 0.2mlFits in whole or in part
Analytik-JenaAlpha SC96 x 0.2mlFits in whole or in part
Analytik-JenaFlexCyclerMonoblock 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
Analytik-JenaFlexCyclerTwinblock 48 x 0.2mlFits in whole or in part
Analytik-JenaFlexCyclerTwinblock Mix 48 x 0.2mlFits in whole or in part
Analytik-JenaSpeedCycler 3636 x 0.2mlFits in whole or in part
Analytik-JenaSpeedCycler²48 x 0.2mlFits in whole or in part
Analytik-JenaSpeedCycler²96 x 0.2mlFits in whole or in part
Analytik-Jena - BiometraTOne 9696 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Analytik-Jena - BiometraTOne 96G96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Analytik-Jena - BiometraTRIO 4848 x 0.2mlFits in whole or in part
Analytik-Jena - BiometraTRIO Combi48-18 48 x 0.2mlFits in whole or in part
ApolloATC20196-48 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
ApolloATC40196 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
ApolloATC70196 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
ApolloATC80196 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Applied Biosystems7500 Fast Real-Time PCR System96 x 0.2ml FastFits in whole or in part, Use with a top-left-cut grid
Applied Biosystems7900HT Fast Real-Time PCR System96 x 0.2ml FastFits in whole or in part, Use with a top-left-cut grid
Applied Biosystems9800 Fast Thermal Cycler96 x 0.2mlFits in whole or in part, Use with a top-left-cut grid
Applied BiosystemsGeneAmp PCR System 960096 x 0.2mlFits in whole or in part
Applied BiosystemsQuantStudio™ 12k Flex96 x 0.1ml FastFits in whole or in part, Use with a top-left-cut grid
Applied BiosystemsQuantStudio™ 3 Real-Time PCR System96 x 0.1ml FastFits in whole or in part, Use with a top-left-cut grid
Applied BiosystemsQuantStudio™ 5 Real-Time PCR System96 x 0.1ml FastFits in whole or in part, Use with a top-left-cut grid
Applied BiosystemsQuantStudio™ 6 Flex96 x 0.1ml FastFits in whole or in part, Use with a top-left-cut grid
Applied BiosystemsQuantStudio™ 7 Flex96 x 0.1ml FastFits in whole or in part, Use with a top-left-cut grid
Applied BiosystemsStepOnePlus™ Real-Time PCR System96 x 0.1mlFits in whole or in part, Use with a top-left-cut grid
Applied BiosystemsStepOne™ Real-Time PCR System48 x 0.1mlFits in whole or in part
Applied BiosystemsVeriti™ 96-Well Fast Thermal Cycler96 x 0.1mlFits in whole or in part, Use with a top-left-cut grid
Applied BiosystemsVeriti™ Dx 96-Well Fast Thermal Cycler96 x 0.1mlFits in whole or in part, Use with a top-left-cut grid
Applied BiosystemsViiA™ 7 Real-Time PCR System Fast96 x 0.1mlFits in whole or in part, Use with a top-left-cut grid
Axygen®MaxyGene™ II96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Azure biosystemsCielo 3 Real Time PCR System96 x 0.2mlFits in whole or in part, Use with a bottom-right-cut grid
Azure biosystemsCielo 6 Real Time PCR System96 x 0.2mlFits in whole or in part, Use with a bottom-right-cut grid
Barnstead ThermolyneAmplitron I96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Barnstead ThermolyneAmplitron II96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
BioerGenePro B-304830-48 48 x 0.2mlFits in whole or in part
BioerGenePro B-48D48 x 0.2mlFits in whole or in part
BioerGenePro B-96G96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
BioerGeneQ TC-24/H(b)24 x 0.2mlFits in whole or in part
BioerLife ECO Thermal Cycler96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
BioerLife Express TC-48/H(t)48 x 0.2mlFits in whole or in part
BioerLife Express TC-96/T/H(a)96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
BioerLifePro TC-96/G/H(b)A96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
BioerLittle Genius TC-24/H24 x 0.2mlFits in whole or in part
BioerLittle Genius TC-25/H25 x 0.2mlFits in whole or in part
BioerXPcycler TC-XP-A96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
BioerXPcycler TC-XP-D48 x 0.2mlFits in whole or in part
BioerXPcycler TC-XP-E48-30 48 x 0.2mlFits in whole or in part
BioerXPcycler TC-XP-G96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
BiomérieuxGENE-UP96 x 0.2ml FastFits in whole or in part, Use with a top-left-cut grid
BioneerMyGenie 96 Gradient Thermal Block96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
Bio-Rad LaboratoriesC100096-Deep WellFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Bio-Rad LaboratoriesC100096-Well FastFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Bio-Rad LaboratoriesC1000Dual 48/48 FastFits in whole or in part
Bio-Rad LaboratoriesC1000 Touch96-Deep WellFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Bio-Rad LaboratoriesC1000 Touch96-Well FastFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Bio-Rad LaboratoriesC1000 TouchDual 48/48 FastFits in whole or in part
Bio-Rad LaboratoriesCFX96 Connect Real-Time PCR Detection System96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Bio-Rad LaboratoriesCFX96 Connect Real-Time PCR Detection System96-Deep WellFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Bio-Rad LaboratoriesCFX96 Opus96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Bio-Rad LaboratoriesCFX96 Real-Time PCR Detection System96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Bio-Rad LaboratoriesCFX96 Real-Time PCR Detection System96-Deep WellFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Bio-Rad LaboratoriesDNA Engine48-48 Alpha unit 48 x 0.2mlFits in whole or in part
Bio-Rad LaboratoriesDNA Engine96v Alpha unit 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Bio-Rad LaboratoriesDNA EngineChromo4 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Bio-Rad LaboratoriesDNA Engine Dyad48-48 Alpha unit 48 x 0.2mlFits in whole or in part
Bio-Rad LaboratoriesDNA Engine Dyad96v Alpha unit 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Bio-Rad LaboratoriesDNA Engine DyadChromo4 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Bio-Rad LaboratoriesDNA Engine Dyad Disciple48-48 Alpha unit 48 x 0.2mlFits in whole or in part
Bio-Rad LaboratoriesDNA Engine Dyad Disciple96v Alpha unit 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Bio-Rad LaboratoriesDNA Engine Dyad DiscipleChromo4 96 x 0.2mlUse with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Bio-Rad LaboratoriesDNA Engine Tetrad 248-48 Alpha unit 48 x 0.2mlFits in whole or in part
Bio-Rad LaboratoriesDNA Engine Tetrad 296v Alpha unit 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Bio-Rad LaboratoriesDNA Engine Tetrad 2Chromo4 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Bio-Rad LaboratoriesMiniOpticon48-12 48 x 0.2mlFits in whole or in part
Bio-Rad LaboratoriesMJ Mini48-12 48 x 0.2mlFits in whole or in part
Bio-Rad LaboratoriesOpticon 296 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Bio-Rad LaboratoriesPTC-10096 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Bio-Rad LaboratoriesS100096-Deep WellFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Bio-Rad LaboratoriesS100096-Well FastFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Bio-Rad LaboratoriesS1000Dual 48/48 FastFits in whole or in part
Blue-Ray BiotechTurboCycler TCST-961096 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Blue-Ray BiotechTurboCycler TCST-962096 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
BoecoTC-PRO 304830-48 48 x 0.2mlFits in whole or in part
BoecoTC-PRO 48D48 x 0.2mlFits in whole or in part
BoecoTC-PRO 96G96 x 0.2mlFits in whole or in part, Use with a top-left-cut grid
Bulldog BioGenePro™ Thermal Cycler30-48 48 x 0.2mlFits in whole or in part
Bulldog BioGenePro™ Thermal Cycler48 x 0.2mlFits in whole or in part
Bulldog BioGenePro™ Thermal Cycler96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Bulldog BioGeneQ™ Thermal Cycler24 x 0.2mlFits in whole or in part
Bulldog BioGeneTouch™ Thermal Cycler30-48 48 x 0.2mlFits in whole or in part
Bulldog BioGeneTouch™ Thermal Cycler48 x 0.2mlFits in whole or in part
Bulldog BioGeneTouch™ Thermal Cycler96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
Bulldog BioLifePro™ Thermal Cycler96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
Bulldog BioLifeTouch™ Thermal Cycler96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
Chai Biotechnologies Inc.OpenQPCR Dual Channel16 x 0.2mlFits in whole or in part
Chai Biotechnologies Inc.OpenQPCR Single Channel8 x 0.2mlFits in whole or in part
DuPont QualiconBAX System Q796 x 0.2mlFits in whole or in part
eENZYMEGenePro Thermal Cycler48 x 0.2mlFits in whole or in part
eENZYMEGenePro Thermal Cycler96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
eENZYMEGeneQ Personal Themal Cycler24 x 0.2mlFits in whole or in part
eENZYMELifeExpress B-96D96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
eENZYMELifeExpress TC-4848 x 0.2mlFits in whole or in part
eENZYMELifeExpress TC-9696 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
eENZYMEMyGene MG-96 Gradient Thermal Cycler96-77 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
eENZYMEMyGene MG-96 Thermal Cycler96-77 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
EppendorfMastercycler96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a top-left-cut grid
EppendorfMastercycler96-77 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a top-left-cut grid
EppendorfMastercycler ep gradient96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a top-left-cut grid
EppendorfMastercycler ep gradient Silver96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a top-left-cut grid
EppendorfMastercycler ep realplex96 x 0.2mlUse with a top-right-cut grid, Use with a top-left-cut grid
EppendorfMastercycler ep realplex Silver96 x 0.2mlUse with a top-right-cut grid, Use with a top-left-cut grid
EppendorfMastercycler gradient96 x 0.2mlFits in whole or in part
EppendorfMastercycler gradient96-77 77 x 0.5mlFits in whole or in part
EppendorfMastercycler nexus96 x 0.2mlFits in whole or in part
EppendorfMastercycler nexus eco96 x 0.2mlFits in whole or in part
EppendorfMastercycler nexus gradient96 x 0.2mlFits in whole or in part
EppendorfMastercycler nexus gradient eco96 x 0.2mlFits in whole or in part
EppendorfMastercycler Personal25-16 25 x 0.2mlFits in whole or in part
EppendorfMastercycler pro96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a top-left-cut grid
EppendorfMastercycler pro S96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a top-left-cut grid
EppendorfMastercycler X50a96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a top-left-cut grid
EppendorfMastercycler X50i96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a top-left-cut grid
EppendorfMastercycler X50l96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a top-left-cut grid
EppendorfMastercycler X50s96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a top-left-cut grid
EppendorfMastercycler X50t384 MicroplateFits in whole or in part, Use with a top-right-cut grid, Use with a top-left-cut grid
EppendorfThermomixer C96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
EppendorfThermomixer comfort96 x 0.2mlUse with a top-right-cut grid, Use with a top-left-cut grid
EricomDeltacycler I96 x 0.2mlFits in whole or in part
EricomDeltacycler II96 x 0.2mlFits in whole or in part
EscoSwift™ Maxi48 x 0.2mlFits in whole or in part
EscoSwift™ Maxi48-30 48 x 0.2mlFits in whole or in part
EscoSwift™ Maxi96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
EscoSwift™ Maxi96 x 0.2ml gradientFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
EscoSwift™ MaxPro48-30 48 x 0.2mlFits in whole or in part
EscoSwift™ MaxPro48-48 48 x 0.2mlFits in whole or in part
EscoSwift™ MaxPro96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
EscoSwift™ Mini25 x 0.2mlFits in whole or in part
EscoSwift™ MiniPro24 x 0.2mlFits in whole or in part
EuroCloneOne Advanced96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
EuroCloneOne Gradient96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a top-left-cut grid
EuroClonepeqSTAR 96 HPL96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
EuroClonepeqSTAR 96 ML96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
EuroClonepeqSTAR 96 Universal96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
Finnzymes InstrumentsPiko™ 24-well24-wellsFits in whole or in part
Finnzymes InstrumentsTCA0096 Arktik96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
Finnzymes InstrumentsTCA4848 Arktik2 x 48 x 0.2mlFits in whole or in part
Gene Technologies Ltd.G-Storm GS148 x 0.2mlFits in whole or in part
Gene Technologies Ltd.G-Storm GS196 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
Gene Technologies Ltd.G-Storm GS196-48 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
Gene Technologies Ltd.G-Storm GS296 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
Gene Technologies Ltd.G-Storm GS448 x 0.2mlFits in whole or in part
Gene Technologies Ltd.G-Storm GS496 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
Gene Technologies Ltd.G-Storm GS496-48 96 x 0.2mlFits in whole or in part
Gene Technologies Ltd.G-Storm GS482248 x 0.2mlFits in whole or in part
Gene Technologies Ltd.G-Storm GSX48 x 0.2mlFits in whole or in part
Gene Technologies Ltd.G-Storm GSX96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
Gene Technologies Ltd.G-Storm GSX96-48 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
Hain-LIFESCIENCEGTQ-Cycler 9696 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Hangzhou Jingle Scientific Instrument Co.,LTD.KF960-A96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
Hangzhou Jingle Scientific Instrument Co.,LTD.KF960-C96-77 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
Helena BiosciencesPhoenix Thermal Cycler96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
Helena BiosciencesProteus Thermal Cycler25 x 0.2mlFits in whole or in part
KyratecSuperCycler96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Lab-Line InstrumentsProgrammable Thermal Block30-48 48 x 0.2mlFits in whole or in part
Lab-Line InstrumentsProgrammable Thermal Block96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
LabnetMultiGene™ II 25 Personal Thermal Cycler25 x 0.2mlFits in whole or in part
LabnetMultiGene™ Mini Personal Thermal Cycler24 x 0.2mlFits in whole or in part
LabnetMultiGene™ Thermal Cycler Gradient TC9600-G96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
LabnetMultiGene™ Thermal Cycler TC960096 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
LandgrafVarius M96 x 0.2mlFits in whole or in part
LandgrafVarius V 8016 x 0.2mlFits in whole or in part
LongGene Scientific Instruments Co.,Ltd.A10096 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
LongGene Scientific Instruments Co.,Ltd.A20096-77 77 x 0.5mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
LongGene Scientific Instruments Co.,Ltd.A20096-77 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
LongGene Scientific Instruments Co.,Ltd.Gradient PCR48 x 0.2mlFits in whole or in part
LongGene Scientific Instruments Co.,Ltd.Gradient PCR96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
LongGene Scientific Instruments Co.,Ltd.L Series 48+48 x 0.2mlFits in whole or in part
LongGene Scientific Instruments Co.,Ltd.L Series 48G48 x 0.2mlFits in whole or in part
LongGene Scientific Instruments Co.,Ltd.L Series 96+96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
LongGene Scientific Instruments Co.,Ltd.L Series 96G96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
LongGene Scientific Instruments Co.,Ltd.Multi-Purpose PCR 96+/Y96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
LongGene Scientific Instruments Co.,Ltd.Multi-Purpose PCR 96G/Y96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
LongGene Scientific Instruments Co.,Ltd.Multi-Purpose PCR L96+/Y96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
LongGene Scientific Instruments Co.,Ltd.Multi-Purpose PCR L96G/Y96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
LongGene Scientific Instruments Co.,Ltd.MyGeneTM PCR48 x 0.2mlFits in whole or in part
LongGene Scientific Instruments Co.,Ltd.MyGeneTM PCR96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
MJ Research Inc.Opticon 2 System96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
MJ Research Inc.Opticon System96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
MJ Research Inc.PTC-10096 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
MJ Research Inc.PTC-10096 x 0.2ml AgVFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
MJ Research Inc.PTC-200 DNA Engine30-48 Alpha unit 48 x 0.2mlFits in whole or in part
MJ Research Inc.PTC-200 DNA Engine48-48 Alpha unit 48 x 0.2mlFits in whole or in part
MJ Research Inc.PTC-200 DNA Engine96v Alpha unit 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
MJ Research Inc.PTC-200 DNA Engine96v Moto Alpha Unit 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
MJ Research Inc.PTC-200 DNA EngineChromo4 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
MJ Research Inc.PTC-220 DNA Engine Dyad30-48 Alpha unit 48 x 0.2mlFits in whole or in part
MJ Research Inc.PTC-220 DNA Engine Dyad48-48 Alpha unit 48 x 0.2mlFits in whole or in part
MJ Research Inc.PTC-220 DNA Engine Dyad96v Alpha unit 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
MJ Research Inc.PTC-220 DNA Engine Dyad96v Moto Alpha Unit 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
MJ Research Inc.PTC-220 DNA Engine DyadChromo4 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
MJ Research Inc.PTC-221 DNA Engine Disciple30-48 Alpha unit 48 x 0.2mlFits in whole or in part
MJ Research Inc.PTC-221 DNA Engine Disciple48-48 Alpha unit 48 x 0.2mlFits in whole or in part
MJ Research Inc.PTC-221 DNA Engine Disciple96v Alpha unit 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
MJ Research Inc.PTC-221 DNA Engine Disciple96v Moto Alpha Unit 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
MJ Research Inc.PTC-221 DNA Engine DiscipleChromo4 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
MJ Research Inc.PTC-225 DNA Engine Tetrad30-48 Alpha unit 48 x 0.2mlFits in whole or in part
MJ Research Inc.PTC-225 DNA Engine Tetrad48-48 Alpha unit 48 x 0.2mlFits in whole or in part
MJ Research Inc.PTC-225 DNA Engine Tetrad96v Alpha unit 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
MJ Research Inc.PTC-225 DNA Engine Tetrad96v Moto Alpha Unit 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
MJ Research Inc.PTC-225 DNA Engine TetradChromo4 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
MJ Research Inc.PTC-240 DNA Engine Tetrad 230-48 Alpha unit 48 x 0.2mlFits in whole or in part
MJ Research Inc.PTC-240 DNA Engine Tetrad 248-48 Alpha unit 48 x 0.2mlFits in whole or in part
MJ Research Inc.PTC-240 DNA Engine Tetrad 296v Alpha unit 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
MJ Research Inc.PTC-240 DNA Engine Tetrad 296v Moto Alpha Unit 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
MJ Research Inc.PTC-240 DNA Engine Tetrad 2Chromo4 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
MWG-BiotechPrimus 96 Advanced96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
MWG-BiotechPrimus 96 Plus96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
MWG-BiotechPrimus Dualblock PCR-System96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
MWG-BiotechPrimus HT Multiblock PCR-System96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
MWG-BiotechPrimus PCR-System96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
PCRMaxAlphaCycler AC-196 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
PCRMaxAlphaCycler AC-296 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
PCRMaxAlphaCycler AC-496 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
PeqlabpeqSTAR 96 HPL96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
PeqlabpeqSTAR 96 ML96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
PeqlabpeqSTAR 96 Universal96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
PeqlabPrimus 96 Advanced96-77 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
PeqlabPrimus 96 Advanced HPL96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
PeqlabPrimus 96 Advanced HT2X96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
PeqlabPrimus 96 Advanced HT4X96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
ProGenThermal Cycler96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
QiagenQIAamplifier96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
QiagenQIAquant 96 2plex96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
QiagenQIAquant 96 5plex96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Rochecobas z 48096 x 0.2mlFits in whole or in part, Use with a bottom-right-cut grid
RocheLightCycler ® 480 Real-Time PCR System96 x 0.2mlFits in whole or in part, Use with a bottom-right-cut grid
RocheLightCycler ® 96 Real-Time PCR System96 x 0.2mlFits in whole or in part, Use with a bottom-right-cut grid
ScinicsEZ-Cycler MP-9696 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
SensoQuestLabcyclerThermoblock 48Fits in whole or in part
SensoQuestLabcyclerThermoblock 96Fits in whole or in part
TaKaRa Bio Inc.PCR Thermal Cycler Dice TP60096 x 0.2mlFits in whole or in part
TaKaRa Bio Inc.PCR Thermal Cycler Dice TP65096 x 0.2mlFits in whole or in part
TechneFlexigene96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
TechneGene-E96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
TechneGenius96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
TechnePrime thermal cycler96 x 0.2mlFits in whole or in part
TechneTC-400096 x 0.2mlUse with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
TechneTC-41296 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
TechneTC-500096 x 0.2mlUse with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
TechneTC-51296 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
TechneTC-Plus96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
TechneTouchgene Gradient96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
Thermo HybaidMultiBlock System96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Thermo HybaidOmn-E96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Thermo HybaidOmnigene TR3 CM22096 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Thermo HybaidPCR Express48 x 0.2mlFits in whole or in part
Thermo HybaidPCR Express96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Thermo HybaidPCR Sprint24 x 0.2mlFits in whole or in part
Thermo HybaidPx296 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Thermo HybaidPxE96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Thermo HybaidTouchDown96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Thermo ScientificPikoReal24-wellFits in whole or in part
ThermoFisher ScientificArktik Thermal Cycler48 x 0.2mlFits in whole or in part
ThermoFisher ScientificArktik Thermal Cycler96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
VWRDuoCycler96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
VWRDuoCycler fast96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
VWRQuattroCycler96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
VWRQuattroCycler fast96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
VWRUnoCycler96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
VWRUnoCycler fast96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
Whatman BiometraT1 Thermocycler96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Whatman BiometraT1 Thermocycler Combi96-77 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Whatman BiometraT3 Thermocycler48 x 0.2mlFits in whole or in part
Whatman BiometraT3 Thermocycler Combi48-18 48 x 0.2mlFits in whole or in part
Whatman BiometraT3000 Thermocycler48 x 0.2mlFits in whole or in part
Whatman BiometraT3000 Thermocycler Combi48-18 48 x 0.2mlFits in whole or in part
Whatman BiometraTGradient96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid
Whatman BiometraTPersonal48 x 0.2mlFits in whole or in part
Whatman BiometraTPersonal Combi48-18 48 x 0.2mlFits in whole or in part
Whatman BiometraTProfessional96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Whatman BiometraTProfessional Basic96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Whatman BiometraTProfessional Basic Gradient96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Whatman BiometraTProfessional Standard Gradient96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Whatman BiometraTProfessional TRIO48 x 0.2mlFits in whole or in part
Whatman BiometraTProfessional TRIO combi48-30 48 x 0.2mlFits in whole or in part
Whatman BiometraTRobot96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Whatman BiometraUNO II96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Whatman BiometraUNO-thermoblock96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Xian Tianlong Science & TechnologyDTC-496-77 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Xian Tianlong Science & TechnologyDTC-4G96-77 96 x 0.2mlFits in whole or in part, Use with a top-right-cut grid, Use with a bottom-right-cut grid, Use with a top-left-cut grid, Use with a grid forming a rigid non-skirted assembly
Fits in whole or in part
The product fits the instrument as a whole or in part.
Use with a top-right-cut grid
Use the product, as a whole or in part, with a grid whose top-right corner is cut. The manufacturer identifies this shape with ABI/Life Technologies regular-profile cyclers, among others.
Use with a bottom-right-cut grid
Use the product, as a whole or in part, with a grid whose bottom-right corner is cut. The manufacturer identifies this shape with 96-well Roche LightCycler 480 instruments, among others.
Use with a top-left-cut grid
Use the product, as a whole or in part, with a grid whose top-left corner is cut. The manufacturer identifies this shape with ABI/Life Technologies fast or 0.1 mL cyclers, among others.
Use with a grid forming a rigid non-skirted assembly
Use the product, as a whole or in part, with a grid that forms a rigid, non-skirted assembly.

Documents

Need assistance?
Contact our experts for support and fast quotations.
(주)이츠바이오
07532 서울특별시 강서구 양천로 551-17 한화비즈메트로 1차 812호
T : 02-3462-8658  F : 02-3462-8659
E-mail : info@itsbio.co.kr
ITSBio, Inc.
812, Hanwha Bizmetro A-dong, 551-17 YangcheonRo, Gangseo-Gu, Seoul, 07532, Korea, Republic of
T : +82-2-3462-8658  F : +82-2-3462-8659
E-mail : info@itsbio.co.kr
Privacy Policy|Terms|© 2026 ITS BIO. All rights reserved.
Online Message
Send to info@itsbio.co.kr