Multifunctional monitoring capability
Measures systolic, diastolic, mean BP, heart rate, tail blood volume and blood flow


Non-invasive blood pressure system
Request QuoteThe CODA® mouse rat tail-cuff system was designed to allow accurate blood pressure measurement in mice and rats. Blood pressure is measured in the tail of the mouse or rat using volume pressure recording (VPR) sensor technology. Using the included software allows you to continuously view data in real-time.
Please Note: Due to temporary parts shortages, some component colors may vary, including the normally black color-coded o-cuff connectors and the normally uncolored cuff storage container.
Need cuffs and animal holders for your CODA Monitor system? Purchase them separately here:
VPR and Occlusion Cuff Kits
Animal Holders
To view our mobile carts, visit our Mobile Carts page.
Measures systolic, diastolic, mean BP, heart rate, tail blood volume and blood flow
Measures mice and rats as small as 8 grams and as large as 950 grams
Able to measure anesthetized animals in a radiological environment
Diastolic blood pressure is measured, not just calculated
Measures awake or anesthetized animals with equal accuracy, consistency, and reliability
Connect up to 6 high throughput controllers to measure up to 48 animals
“We have used the CODA system for measurement of blood pressure in obese Zucker rats, and are satisfied with the results.”
The animal nose cone holders that accompany the CODA system were specifically designed for non-invasive tail-cuff blood pressure measurements. The clear acrylic holders provide unrestricted breathing and allow complete visibility to the researcher.
The VPR sensor incorporates a specially designed differential pressure transducer that measures the systolic and diastolic blood pressure by determining the blood volume in the tail. We have cuff sizes for mice as small as 8 grams to rats as large as 950 grams.
| Standard | Extended | Premium | |
|---|---|---|---|
| Coverage period | 1 year | Additional 2 years | Additional 2 years |
| Controller | |||
| Loaner equipment (for use under warranty repairs) | | |
Unlimited
|
| Loaner equipment — shipping (for use under warranty repairs) |
Next day
| ||
| Onsite installation & training |
Unlimited
| ||
| Expedited repairs (any repairs) |
24 hours
|
Approximately 45° C when positioned flat. Folding the sides over can increase the temperature around the pad significantly.
W: 32.5″H: 10.5″D: 22″
Yes, the CODA accommodates both mice and rats. CODA cuffs and animal holders are available for small mice from 8g to large rats over 500g.
The CODA Monitor measures a single animal’s blood pressure; the CODA High Throughput Systems are able to measure 2, 4, 6 or 8 animals simultaneously. Up to 6 CODA HT8’s can be combined to measure a total of 48 animals simultaneously.
The CODA software controls CODA High-Throughput systems, and is designed to record and organize your blood pressure data. The CODA software is also compatible with CODA Monitor, though it is not required.
Yes, the controller can be sterilized with hydrogen peroxide gas (or VHP). You may use the same sterilization protocol used for laptop computers and other electronics in your facility. Be sure to open any caps or ports to allow the gas to reach inner mechanisms and tubing, if applicable.

For use with the CODA® High Throughput non-invasive blood pressure system. All cuffs come with tubing, connectors, and extra bladders.

For use with the CODA® High Throughput non-invasive blood pressure system. All cuffs come with tubing, connectors, and extra bladders.

Clear animal holders with black nose cones are ideal for animal research because they allow the researcher to constantly observe the animal’s behavior. A trained rat or mouse can comfortably and quietly remain in our holder for several hours. Animal nose cone holders for use with the CODA® High Throughput System. Holder fit may vary […]